The office air conditioning stopped cooling: what to check in the first hours

The office air conditioning stopped cooling: what to check in the first hours

In short: when the air conditioning in an office or store stops cooling, there are six safe checks a facility manager can make in the first minutes: thermostat, breaker, filter, ice on the unit, condensate drain and outdoor condenser. If there is ice, the unit is switched off immediately. Refrigerant and electrical connections are a technician’s job, and the EPA requires certification for anyone handling refrigerant. When equipment fails often, preventive maintenance is what fixes the problem.
Contents of this guide
  1. Six safe checks
  2. Symptoms and common causes
  3. What not to do
  4. After the emergency
  5. Frequently asked questions
  6. Sources

Note: most of the manufacturer guides in this list (Carrier, Trane, DOE) are written for residential equipment. NREL’s rooftop unit guide is the source specific to commercial equipment. Adapting them to an office is Radar Panamá’s judgment.

Six safe checks

  1. Thermostat. It should be in cool mode with the desired temperature set. The DOE adds checking the batteries. Carrier · DOE.
  2. Breaker and fuse. Look for a breaker in the off position or a blown fuse. Carrier warns that electricity is dangerous and that a breaker should be reset only by someone comfortable doing so. Carrier.
  3. Filter. A clogged filter restricts airflow and reduces cooling capacity. Before cleaning or changing it, Trane says to turn the unit off and switch off the breaker that powers it. Trane.
  4. Ice or frost. If ice is visible, the system is switched off immediately to avoid compressor damage. On the thermostat, switch from cool to off and let it defrost. If the unit freezes again after changing the filter and clearing the drain, it is time to call a technician. Trane.
  5. Condensate drain. The DOE says to check that it is not clogged. On units with an overflow switch, a drain blocked by dirt, mold or spider webs can shut down the compressor and the condenser fan. Trane.
  6. Outdoor condenser. Clear leaves and debris from the fan, the compressor and the condenser. DOE.
Key fact: if the unit shows ice or frost, it should be switched off immediately: according to Trane, continuing to run with a frozen evaporator can damage the compressor of the outdoor unit.

Symptoms and common causes

SymptomCommon causeWho fixes it
Air comes out, but barely coldDirty filter or dirty coils, which reduce cooling capacity and make the system run longerThe manager changes the filter; the coil, a technician
Frost on the copper lineDirty filter, blocked return or low refrigerantSwitch off the unit; technician if it repeats
The unit does not startThermostat, breaker, fuse or a clogged drain with an overflow switchThe manager checks; if it persists, a technician
Runs for hours and does not coolRefrigerant leak or dirty coilsCertified technician
Turns on and off frequentlyWorn compressor and fan controlsTechnician

Sources: DOE, ENERGY STAR, Carrier and Trane.

What not to do

  • Switching the unit on and off again and again. The DOE warns that cycling too often wears out the compressor and fan controls.
  • Touching the electrical connections. The DOE says to contact a professional to check them.
  • Topping off gas without finding the leak. The EPA recommends asking the technician to locate and repair the leak instead of just recharging. See the EPA guide.
  • Leaving the refrigerant to just anyone. In the US, the EPA requires Section 608 certification for anyone handling refrigerant and lets you ask the technician to show a credential. It is a rule of that country, useful as a reference for asking a contractor about their training. EPA requirements.

After the emergency

Equipment that fails during working hours has almost always been giving warnings. NREL’s guide for commercial rooftop units recommends checking filters, coils and the condensate drain every quarter, and refrigerant lines every year, and notes that routine maintenance reduces the risk of failure and downtime. See the NREL guide. The same guide suggests that a contract define whether it includes emergency repairs, on which days and hours, and how quickly the contractor must respond. The article on the maintenance contract details what to demand.

Climatiza Panamá, an HVAC service company in Panama City, says its contract clients get a priority attention line and a preferential rate on corrective work. Its Priority level adds the priority attention line and minor corrective work included, and its website has an Urgencias (emergencies) WhatsApp button.

Does your air conditioning fail often, or do you want to stop finding out only after it fails?
Climatiza Panamá maintenance comes at three levels; contract clients have a priority attention line.

See the contract maintenance of Climatiza Panamá

Frequently asked questions

Why is the office air conditioning not cooling?

The most common causes are a misconfigured thermostat, a dirty filter, dirty coils, a frozen evaporator, a clogged drain or a refrigerant leak.

Can I keep using the air conditioning if it has ice?

No. Switch it off immediately and let it defrost. Running with a frozen evaporator can damage the compressor.

What should I check before calling the technician?

The thermostat, the breaker and fuse, the filter, whether there is ice, the drain and that the outdoor condenser is clear.

Who can recharge the refrigerant?

A trained technician. If the unit loses refrigerant there is a leak, and the right move is to locate and repair it, not just recharge.

Does a maintenance contract cover emergencies?

It depends on what was agreed. Climatiza says its contract clients have a priority attention line and a preferential rate on corrective work.

Related articles

Sources

Radar answers

Ask about this article

Type your question and we will show you the answer inside this article or in other Radar Panamá publications.

Was this article useful?
By Deilys Romero

Deilys Romero is a writer at Radar Panamá. A business administrator with a specialisation in accounting, Venezuelan, 48, she covers the economy, companies, taxes and SME management with a practical approach. Based between Panama and Colombia, she closely follows the business activity of both countries.